Evaluation of the Cylinder Implant Thread Height and Width: A 3-dimensional Finite Element Analysis

Liang Kong, DDSc/Kaijin Hu, DDSc/Dehua Li, DDSc/Yingliang Song, DDSc/Jin Yang/Ziyan Wu/Baolin Liu, DDSc


PMID: 18416414

Purpose: To evaluate continuous and simultaneous variations of thread height and width for an experimental screw-type implant. Materials and Methods: A finite element model of an implant with a V-shaped thread was created. The range of thread height was set at 0.20 to 0.60 mm, and the range of thread width was set at 0.10 to 0.40 mm. Forces of 100 N and 50 N were applied along the implant axis (AX) and an angle of 45 degrees in a buccolingual direction (45-degree BL), respectively. The maximum von Mises stresses in jawbone were evaluated, and the sensitivity of the stress in jawbone to the variables was also evaluated. Results: Under AX load, the maximum von Mises stresses in cortical and cancellous bones increased by 4.3% and 63.0%, respectively, as thread parameters changed. Under 45-degree BL load, maximum von Mises stresses in cortical and cancellous bones increased by 19.3% and 118.0%, respectively. When thread height was from 0.34 to 0.50 mm and thread width was 0.18 to 0.30 mm, the tangent slope of the maximum von Mises stress response curve ranged from 1 to 1. The variation of the maximum von Mises stresses in jawbone was more sensitive to thread height than to thread width. Conclusions: Stress in cancellous bone is more likely to be influenced by thread parameters than stress in cortical bone. A 45-degree BL force is more likely to be influenced by thread parameters than an axial force. A thread height of 0.34 to 0.50 mm and a thread width of 0.18 to 0.30 mm is optimal from a biomechanical point of view. In the design of a screw-type implant, thread height is more important than thread width for the reduction of stress within the bone. Int J Oral Maxillofac Implants 2008;23:6574

Key words: 3-dimensional finite element analysis, dental implant, optimized thread design, stress


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help