Accuracy of Impressions and Casts Using Different Implant Impression Techniques in a Multi-implant System with an Internal Hex Connection

Hans-Jrgen Wenz, Prof Dr Med Dent/Hans-Ulrich Reuter, Dr Med Dent/Katrin Hertrampf, Dr Med Dent, MPH


PMID: 18416411

Purpose: The aim of this study was to investigate the deviations of the implant positions of both impressions and casts using different impression materials and techniques. Furthermore, the existence of a correlation between the deviations of the impression and those of the cast was investigated. Materials and Methods: A reference model was fabricated with 5 Frialit-2 implants parallel to each other. In a standardized experimental setting, 5 stone casts were produced with 5 different techniques using polyether (A) or polyvinyl siloxane (B through E). In 3 groups, a direct technique was used with a medium-viscosity material or a putty-tray material in combination with a light-viscosity syringe material (A to C). In 2 groups, an indirect technique (either 1-step [group D] or 2-step [group E] was used with a putty-tray material in combination with a light-viscosity syringe material. The center-to-center distances were measured for impressions and casts in the horizontal plane using a computer-aided microscope, and the relative and absolute deviations compared to the reference model were calculated. Analysis of variance followed by the post-hoc Scheff test (parametric data) or the Kruskal-Wallis test followed by pair-wise Mann-Whitney tests (nonparametric data) were used for statistical analyses. Deviations of impressions were compared with their respective casts using paired t tests and the Pearson correlation coefficient. Results: No significant differences for the relative deviations were found for impressions (5 to 8 m) or casts (+7 to +16 m). Group E produced significantly higher absolute deviations for impressions (38 m) and casts (39 m) compared to the other groups (11 to 18 m and 17 to 23 m, respectively). A significant correlation between deviation of the impression and its respective cast was found for every group (r = 0.40 to 0.80) except group D. Conclusions: The distortions in the horizontal plane of the casts obtained from the impression techniques of groups A to D would probably not affect the clinical fit of implant-retained superstructures. Because of the high variation of deviations (113 to +124 m), the 2-step technique cannot be recommended. The method to measure both impression and cast provided a better understanding of how inaccuracies are caused. Int J Oral Maxillofac Implants 2008;23:3947

Key words: dental implants, impression materials, impression technique, transfer coping


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help