Evaluation of the Accuracy of Implant-Level Impression Techniques for Internal-Connection Implant Prostheses in Parallel and Divergent Models

Jung-Han Choi, DDS, MSD/Young-Jun Lim, DDS, MSD, PhD/Soon-Ho Yim, DDS, MSD, PhD/Chang-Whe Kim, DDS, MSD, PhD


PMID: 17974110

Purpose: This study evaluated the accuracy of 2 implant-level impression techniques (direct nonsplinted and splinted) for the fabrication of multi-unit internal-connection implant restorations in 2 simulated clinical settings (parallel and divergent) using a laboratory model. Materials and Methods: A dental stone master model was fabricated with 2 pairs of implant replicas. One pair simulated a parallel clinical condition and the other an 8-degree–divergent condition. Ten stone casts were made from vinyl polysiloxane impressions of the master model for each impression technique. Half of the samples were created by a direct nonsplinted technique (square impression copings, custom tray), and the other half were made by a direct splinted technique (square impression copings splinted with autopolymerizing acrylic resin, custom tray). Four strain gauges were fixed on each metal framework to measure the degree of framework deformation for each stone cast in half-Wheatstone-bridge formations. Deformation readings were made twice in 4 directions (anterior, posterior, superior, and inferior). Deformation data were analyzed using repeated-measures analysis of variance at a .05 level of significance. Results: No significant difference in deformation was found between the direct nonsplinted and splinted samples in either simulated clinical condition (P > .05). No significant difference in deformation was found between the techniques regardless of condition (P > .05). Conclusions: Within the limitations of this study, using a 2-implant model, the accuracy of implant-level impressions for internal-connection implant restorations was similar for the direct nonsplinted and splinted techniques in settings with divergence up to 8 degrees. Int J Oral Maxillofac Implants 2007;22:761–768

Key words: implant divergence, implant-level impression, internal connection implant, strain gauge


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help