Share Page:

Volume 22 , Issue 2
March/April 2007

Pages 226–234

Clinical Evaluation of a Prospective Multicenter Study on 1-piece Implants. Part 1: Marginal Bone Level Evaluation After 1 Year of Follow-up

Kaj Finne, DDS / Eric Rompen, DDS, PhD / Joseph Toljanic, DDS

PMID: 17465347

Purpose: The aim of the present investigation was to evaluate the marginal bone level after 1 year of follow-up of 1-piece implants after immediate provisional restoration fabrication. Materials and Methods: Patients received NobelDirect and NobelPerfect 1-piece implants (Nobel Biocare, Göteborg, Sweden) that were immediately restored and placed into function as part of a 3-year, multicenter investigation. Life table analysis was used for evaluation of implant cumulative survival rates. The Student t test (for dichotomous variables) and Pearson correlation (for continuous and ordered categorical variables) were used to estimate the influence of separate parameters on marginal bone. Results: Eighty-seven patients received 152 NobelDirect or NobelPerfect 1-piece implants. Of these, 81 patients returned for the 1-year follow-up and 21 for the 2-year follow-up. Three implants were lost, resulting in a cumulative survival rate of 97.9% after up to 2 years. The average marginal bone level at implant placement was 0.33 mm (SD 1.20, n = 141) superior to the reference point (lower edge of the implant collar). Marginal bone level was –0.77 mm (SD 1.33, n = 138) at 6 months and –0.98 mm (SD 1.38, n = 123) at 1 year. Average bone level at the 2-year follow-up was 0.17 mm (SD 1.20, n = 26). After 1 year of loading, bone level in the maxilla was more apical compared to that in the mandible (P = .05), and a positive correlation was found between bone level at placement and bone level at 12 months (P = .008). Shallow implant positioning resulted in less marginal bone remodeling compared to deep implant positioning. Conclusion: On the basis of this prospective multicenter study, stable marginal bone level and soft tissue support the hypothesis that the 1-piece implant has the capacity to preserve both hard and soft tissue. Int J Oral Maxillofac Implants 2007;22:226–234

Key words: bone level, immediate function, 1-piece dental implants, radiologic evaluation

Full Text PDF File | Order Article


Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.


© 2015 Quintessence Publishing Co, Inc JOMI Home