LOGIN
 
Share Page:
Back

Volume 21 , Issue 5
September/October 2006

Pages 747755


Displacement of Implant Components from Impressions to Definitive Casts

Sunjai Kim, DDS, PhD / Jack I. Nicholls, PhD / Chong-Hyun Han, DDS, PhD / Keun-Woo Lee, DDS, PhD


PMID: 17066636

Purpose: Four possible displacements of implant components from a patient model to a definitive cast were assessed to suggest a standard method of comparing the accuracies of implant impression techniques. Materials and Methods: Two techniques for impression making were assessed: a nonsplinted open-tray technique and a light-curing resin splinted open-tray technique. A mandibular model with 5 parallel implants was fabricated. Five definitive casts were fabricated per technique. Using a computerized coordinate measuring machine, 5 part coordinate systems were established, and 7 sets of data were obtained for each sample. From the data, the amount of displacement while connecting components and the linear and angular displacement of components during impression making and cast fabrication were calculated. The Mann-Whitney test was used to determine significant differences between the impression techniques (P < .05). Results: The average displacements while connecting impression copings and abutment replicas were 31.3 and 30.4 m, respectively. Less displacement occurred in the nonsplinted group compared to the splinted group during impression making (P = .001) but greater displacement occurred in that group during definitive cast fabrication (P = .015). Discussion: In contrast to previous studies, the current study excluded displacement resulting from component connection, because displacement from that source has no relation to impression technique and cannot be controlled. Conclusions: Connecting a component produced as great a displacement as that resulting solely from a impression or cast fabrication. The nonsplinted group was more accurate during impression making but less accurate during cast fabrication. Int J Oral Maxillofac Implants 2006;21:747755

Key words: coordinate measuring machine, displacement, implant, impression


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help