Removal Torque of Miniscrews Used for Orthodontic Anchorage - A Preliminary Report

Yi-Jane Chen, DDS, MSD / Yuan-Hou Chen, DDS, MSD / Li-Deh Lin, DDS, PhD / Chung-Chen Jane Yao, DDS, PhD


PMID: 16634500

Purpose: Implant anchors such as miniscrews and miniplates have been loaded immediately for anchorage during orthodontic treatment. The purpose of this study was to measure the removal torque of immediately loaded miniscrews after clinical usage and to determine the possible factors associated with this value. materials and methods: From 29 patients with malocclusions, 46 miniscrews were removed, and removal torque was measured with a torque gauge. Removal torque values were subjected to statistical analysis for possible association of different clinical characteristics. Results: The mean removal torque value was 1.10 kgcm, and removal torques for 50% of the implants were greater than 0.89 kgcm (8.7 Ncm). Removal torque values were significantly higher in the mandible than in the maxilla. The removal torques of 15-mm and 17-mm miniscrews were significantly higher than those of 13-mm miniscrews. Therefore, the site of implantation and miniscrew length were important factors associated with removal torque. However, there was no significant correlation between the removal torque value and age, gender, healing time, or time in function. Discussion: When miniscrews are used as anchorage for uprighting tipped molars, excessive torque in a counterclockwise direction may loosen them. From the measurements obtained in this investigation, miniscrews can sufficiently sustain an uprighting moment. Conclusion: The removal torque values of the majority of miniscrews in this study population when loaded immediately as orthodontic anchorage were greater than 0.89 kgcm, and this was sufficient for these implants to fulfill their purpose as anchors in 3-dimensional tooth movements.

Int J Oral Maxillofac Implants 2006;21:283289
Key words: dental implants, miniscrews, osseointegration, removal torque


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help