LOGIN
 
Share Page:
Back

Volume 21 , Issue 2
March/April 2006

Pages 275–282


Influence of Prosthetic Parameters on the Survival and Complication Rates of Short Implants

Georges Tawil, DDS, DSc, OD / Nadim Aboujaoude, DCD / Roland Younan, DCD, DES


PMID: 16634499

Purpose: Implants shorter than 10 mm can be a long-term solution for sites with limited bone height. The purpose of this study was to determine the influence of some prosthetic factors on the survival and complication rates. materials and methods: Two hundred sixty-two short machined-surface Brånemark System implants were consecutively placed in 109 patients and followed for a mean of 53 months. The prosthetic parameters were recorded, and the data were examined for relation to peri-implant bone loss and biologic or biomechanical complications. Results: Relatively few crown-to-implant (C/I) ratios were < 1 or > 2 (16.2%). Occlusal table (OT) width ranged from 5.4 to 8.3 mm. Opposing dentition was most often natural teeth, a fixed prosthesis supported by natural teeth, or an implant-supported fixed restoration. Occlusion with a normal buccolingual maxillomandibular relationship was found in 72.7% of the cases. No significant difference in peri-implant bone loss was correlated with C/I ratio or OT. Neither cantilever length nor bruxism had a significant effect on peri-implant bone loss. Mean bone loss was 0.74 ± .65 mm. The difference in the complication rate (15% overall) between the bruxer and the nonbruxer group was not statistically significant (P = .51). One implant was lost in a heavy bruxer after 7 years of function. Discussion: Increased C/I and OT values do not seem to be a major risk factor in cases of favorable loading. In 67% of the cases, the mesiodistal length of the prosthesis was less than the corresponding natural tooth length, which may have contributed to better load distribution and more favorable results. Conclusions: Short implants appear to be a long-term viable solution in sites with reduced bone height, even when the prosthetic parameters exceed the normal values, provided that force orientation and load distribution are favorable and parafunction is controlled. (Case Series)

Int J Oral Maxillofac Implants 2006;21:275–282
Key words: crown-implant ratios, implant complication rates, prosthetic parameters, short implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help