Evaluation of Loading Conditions on Fatigue-Failed Implants by Fracture Surface Analysis

Haw-Ming Huang, MS/Chih-Mong Tsai, DDS, PhD/Cheng-Chung Chang, DDS, MS/Che-Tong Lin, DDS, PhD/Sheng-Yang Lee, DDS, PhD


PMID: 16392341

Purpose: The goal of this study was to determine the relationship between fracture surface morphology and applied stress level for dental abutment screws loaded in cyclic fatigue. If a correlation between fracture surface and load level can be determined, then the fracture surface analysis could be used as a tool to assess the mechanism by which a screw failed and the magnitude of the load at which it failed. Materials and Methods: Test implants were loaded with static and cyclic forces. In the cyclic test, the load versus the number of cycles was plotted as a curve for biomechanical analysis. The fracture surfaces of the failed screws were observed and recorded using scanning electron microscopy (SEM). Results: Two fracture phases, a smooth region and a rough region, were observed on the fracture surface. After identifying the boundary between the 2 regions, the smooth region ratio (SRR), the ratio of the smooth phase area to the area of the whole fracture surface, was measured using digitized SEM images. The mean SRRs were 0.60 0.03, 0.66 0.03, and 0.75 0.03 when the tested implants were subjected to dynamic loading of 60%, 55%, and 50% ultimate failure loading (UFL), respectively. Linear relationships were found between the SRR values and loading magnitude and between SSR and number of cycles. Discussion: The smooth area on the fracture surface can be used to assess the load conditions and internal stress of fatigue-fractured implants. Conclusions: These results demonstrate that fracture surface analysis of fractured implants has the potential to become a useful indicator for assessing implant fracture mechanisms. Int J Oral Maxillofac Implants 2005;20:854859
Key words: dental implants, fatigue, finite element analysis, implant fractures, scanning electron micrography


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help