Membrane Durability and Tissue Response of Different Bioresorbable Barrier Membranes: A Histologic Study in the Rabbit Calvarium

Thomas von Arx, PD Dr Med Dent/Nina Broggini, DMD, MS, Dr Med Dent/Simon Storgard Jensen, DDS/ Michael M. Bornstein, Dr Med Dent/Robert K. Schenk, Prof Dr Med/Daniel Buser, Prof Dr Med Dent


PMID: 16392340

Purpose: The objective of the present study was to histologically evaluate barrier durability and host tissue response of new prototype collagen membranes in comparison to clinically available collagen and synthetic polymer membranes. Materials and Methods: The experimental study was conducted in 20 rabbits with 4 different healing periods of 2, 6, 12, and 28 weeks. Following surgical exposure of the calvarium, 6 circular bone defects (diameter 4 mm, depth 1.5 mm) were drilled into the outer cortex. After the bone had been removed, each defect was covered with 1 of 6 different membranes: 3 collagen prototype membranes, a Bio-Gide collagen membrane (BG), a glycolide-lactide-trimethylene carbonate Osseoquest membrane (OQ), and a polylactide Atrisorb membrane (AS). Histological analysis was performed following staining with toluidine blue and transversal sectioning of the calvarial bone. Results: All collagen membranes showed similar tissue integration characterized by fibrous encapsulation with differentiation of a periosteumlike tissue upon the external bony surface. One prototype collagen membrane displayed clearly longer membrane integrity. The evaluated synthetic membranes demonstrated extended barrier durability but also exhibited inflammatory foreign-body reactions. Discussion: Recent experimental investigations have shown that degradation of collagen membranes may begin within days to weeks of membrane placement. This was confirmed in the present study. However, 1 of the chemically modified collagen prototype membranes exhibited prolonged membrane integrity in the absence of an inflammatory tissue response. Conclusion: Further investigation of the prototype membrane that showed prolonged membrane integrity to evaluate its potential in GBR procedures is needed. Int J Oral Maxillofac Implants 2005;20:843853
Key words: aliphatic polymers, bioresorbable barrier membranes, collagen, membrane degradation, tissue reactions


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help