LOGIN
 
Share Page:
Back

Volume 20 , Issue 4
July/August 2005

Pages 627631


Correction of a Malpositioned Endosseous Implant by a Segmental Osteotomy: A Case Report

Gerry M. Raghoebar, DDS, MD, PhD/Anita Visser, DDS/Arjan Vissink, DDS, MD, PhD


PMID: 16161748

A mandibular overdenture supported by 2 or 4 endosseous implants has been proven to be a reliable treatment modality for patients suffering from conventional denture problems. However, fabrication of an implant-retained mesostructure to support an overdenture is not possible in all cases. Malpositioning of implants is a common cause of failure in such cases. A case is presented in which a ball attachment caused pain and severe swelling of the floor of the mouth because of the lingual inclination of an endosseous implant. The lingual inclination of the implant was corrected by a segmental osteotomy. Six weeks later, prosthodontic treatment began, and the resultant overdenture supported by a Dolder bar was quite acceptable for the patient.
Int J Oral Maxillofac Implants 2005;20:627631

Key words: endosseous dental implants, malpositioned implants, osteotomy


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help