LOGIN
 
Share Page:
Back

Volume 13 , Issue 4
July/August 1998

Pages 500–505


A Comparative Clinical Study of Three Different Endosseous Implants in Edentulous Mandibles

Anne-Karine Røynesdal, DDS, Eirik Ambjørnsen, DDS, PhD, Sven Støvne, DDS, Hans R. Haanæs, DD, MD, PhD.


PMID: 9714956

The purpose of this prospective study was to investigate the clinical outcome and marginal bone resorption of three different endosseous implants placed in the anterior mandibles of 15 elderly patients. Eleven women and 4 men (ranging from 65 to 80 years, mean 71 years) had three different endosseous implants placed in the anterior mandible; one titanium plasma-sprayed cylinder implant (4-mm diameter), one titanium cylinder implant with hydroxyapatite coating (4-mm diameter), and one standard threaded titanium implant (3.75-mm diameter). Three months later, at the second-stage surgical procedure, ball abutments were connected and an overdenture was placed. At 12, 24, and 36 months, marginal bone resorption and Periotest values were recorded. None of the implants was lost in this period. An analysis of variance with repeated measurement was performed annually to test the existence of significant differences between the implants. When differences appeared, paired t tests were used to identify which differences were significant. Bonferroni multipliers were used to adjust for multiple testing. When marginal bone resorption was concerned, threaded titanium and hydroxyapatite-coated implants had significantly better scores than titanium plasma-sprayed cylinder implants. Periotest values for hydroxyapatite-coated implants were significantly better than test values for the other implants after 2 years. After 3 years significance was obtained between hydroxyapatite and screw-shaped implants only (P < .05). It was concluded that titanium plasma-sprayed cylinder implants have a less favorable prognosis than the other implants used in this study. (INT J ORAL MAXILLOFAC IMPLANTS 1998;13:500–505) Key words: clinical follow-up, hydroxyapatite-coated implants, marginal bone resorption, overdentures, titanium plasma-spray–coated implants, titanium threaded implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help