LOGIN
 
Share Page:
Back

Volume 33 , Issue 5
September/October 2018

Pages 1011–1018


Effect of Plasma Oxidation–Treated TiOx Film on Early Osseointegration

Huanhuan Jiang, DDS, MSc/Taowen Zhang, DDS, MSc/Wenjuan Zhou, DDS, MSc/Zeng Lin, PhD/Zhonghao Liu, DDS, PhD


PMID: 30231086
DOI: 10.11607/jomi.6680

Purpose: To develop a TiOx film with high wettability using plasma oxidation methodology and to evaluate the effect of such surface modification on new bone formation and early osseointegration. Materials and Methods: Twenty sandblasted and acid-etched (SLA) titanium implants layered with a TiOx film layer were modified by plasma oxidation using a Radio Frequency Plasma Enhanced Chemical Vapor Deposition (RFPECVD) system. Twenty SLA implants without any treatment were employed as the control group. Scanning electron microscopy was used to evaluate surface morphology of the coating. X-ray photoelectron spectroscopy (XPS) was utilized to identify the chemical composition of the implant surface, and the wettability was tested with the help of the contact angle calculation. All implants were randomly inserted into the proximal tibia of 20 rats with a split-plot design. Four weeks after implantation, early osseointegration of the two groups was analyzed by a removal torque test and histologic analysis. Results: The surface characteristics showed that both SLA and plasma oxidization–treated SLA (PO-SLA) surfaces displayed similar typical isotropic irregular indentations. As revealed by the XPS analyses, both TiO2 and Ti2O3 were coexistent in the PO-SLA surface. The contact angle measurement revealed that the super-hydrophilic surface was created out in the PO-SLA surface. Four weeks after implantation, a higher removal torque value was observed in the group of implants with the PO-SLA surface compared with the control group (12.68 ± 1.07 vs 9.95 ± 1.42 Ncm, P < .05), and a higher rate of bone-to-implant contact was also detected in the same group of implants with the PO-SLA surface (47.79% ± 9.59% vs 39.41% ± 9.00%, P < .05). The bone area ratio was also higher in the PO-SLA surface group than the control group (39.10% ± 10.01% vs 29.01% ± 7.24%, P < .05). Conclusion: It was indicated that the PO-SLA surface has combined the effect of high wettability and micro/nano-structures to notably increase early bone apposition.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2019 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help