Effect of Buccal Implant Inclination on Stresses Around Two-Implant-Retained Overdentures with Resilient Stud Attachments


Moustafa Abdou Elsyad, BDS, MSc, PhD/Karima Salah Abid, BDS/Elsayed Abd Elkhalek, BDS, MSc, PhD


PMID: 28403248
DOI: 10.11607/jomi.5427

Purpose: This study aimed to evaluate the effect of buccal implant inclination on stresses around two-implant-retained overdentures with resilient stud attachments. Materials and Methods: Four acrylic models representing a mandibular edentulous ridge were constructed. For each model, two implants were placed at canine areas. Models were classified into four types according to the degree of buccal implant inclination: Group I (GI, 0 degrees), Group II (GII, 10 degrees), Group III (GIII, 20 degrees), and Group IV (GIV, 30 degrees). Overdentures were connected to the implants with Locator attachments. Regular light-retention inserts were used for all groups, and extended range inserts were also used for GIV (GIVext), making a fifth comparison group. Four strain gauges were bonded at the buccal, lingual, mesial, and distal surfaces of each implant to monitor the stresses during bilateral and unilateral load application. Results: Tensile stresses were recorded at distal and lingual gauges, and compressive stresses were recorded at mesial and buccal gauges for all groups. GIV recorded the highest stresses, followed by GIII, GII, GIVext, and GI. Distal position recorded the highest stresses, followed by lingual, mesial, and buccal. Nonloading side was associated with significantly higher stresses than loading side. Conclusion: The peri-implant stresses increase as the buccal implant inclination increases when resilient stud attachments are used for implant overdentures. Therefore, it is recommended to insert the implants parallel to each other to decrease peri-implant stresses. However, when buccal inclination is inevitable due to anatomical limitations, it should be limited to 10 degrees for standard nylon inserts, or extended range inserts are recommended.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help