Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading

Luis Eduardo Butignon, DDS, MSc, PhD/Mariana de Almeida Basílio, DDS, MSc/Julia Sgavioli Santo/João Neudenir Arioli Filho, DDS, MSc, PhD


PMID: 27632255
DOI: 10.11607/jomi.4477

Purpose: Little information is available in the literature regarding the accuracy of marginal fit of abutments made from different materials. The aim of this study was to compare the level of vertical misfit in abutments made from different materials before and after cyclic loading. Materials and Methods: Thirty external hexagon implants, 3.75-mm diameter and 13-mm length, were embedded in epoxy resin and divided into three groups according to abutment type (n = 10): (1) machined titanium (Ti) abutments; (2) premachined gold-alloy (Au) abutments; and (3) machined zirconia (Zr) abutments. The abutments were attached to their respective implants by titanium alloy screws at the manufacturer’s recommended torque. A cyclic loading (0.5 × 106 cycles; 15 Hz) between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants. Implant-abutment vertical misfits (μm) were measured at four predetermined points before and after loading with a stereomicroscope at 60× magnification. The group means were compared using a three-way repeated-measure analysis of variance (ANOVA) and Tukey test (α = .05). Results: The results from the ANOVA identified significant effects of the abutment type (P < .001). However, there were no significant effects of cyclic loading (P = .978) or measured surfaces (P = .955). When the abutment groups were compared regardless of cyclic loading and measured surfaces, the Au group showed the highest value of vertical misfit (14.93 ± 0.78), followed by the Ti group (8.53 ± 0.44) and the Zr group (5.64 ± 0.73), with statistically significant differences among them (P < .05). Conclusion: The abutment groups showed statistically significant differences in vertical misfit. Zr abutments showed the highest accuracy in terms of marginal fit, and Au abutments showed the lowest. Cyclic loading did not significantly change the level of vertical misfit. All experimental groups presented acceptable values of marginal misfit.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help