LOGIN
 
Share Page:
Back

Volume 31 , Issue 2
March/April 2016

Pages 459468


Comparison of Initial Implant Stability of Implants Placed Using Bicortical Fixation, Indirect Sinus Elevation, and Unicortical Fixation

Andrea Hsu, DMD, MS/Wook-Jin Seong, DDS, PhD/Ryan Wolff, DDS/Lei Zhang, MS/James Hodges, PhD/Paul S. Olin, DDS, MS/James E. Hinrichs, DDS, MS


PMID: 27004293
DOI: 10.11607/jomi.4142

Purpose: The aim of this study was to determine if self-threading dental implants placed using stopper drills to bicortically engage both the alveolar crest and sinus floor (bicortical fixation) achieved primary and/or secondary stability comparable to that of short implants only engaging alveolar crest cortical bone (unicortical fixation) or implants engaging both the crest and sinus floor but via greenstick fracture and grafting (indirect sinus elevation). Materials and Methods: Thirty-eight patients exhibiting 7 to 11 mm of bone coronal to the sinus floor as confirmed by preoperative CBCT were recruited. Forty-five implants were randomly assigned to one of the placement techniques. No patient received more than two implants, which were placed in opposite sides of the maxilla while using different surgical techniques. An Osstell ISQ was employed immediately after implant placement to measure stability six times in a buccolingual dimension. Secondary stability was measured at stage-two surgery after a 3- to 6-month healing period. Results: The greatest primary implant stability was achieved via indirect sinus elevation. However, no statistically significant difference was found among the three surgical techniques (P = .13; bicortical fixation: 71.4 [standard error = 2.1]), unicortical fixation: 69.6 [2.1], indirect sinus elevation: 75.9 [2.3]). The three techniques had similar secondary stability (P > .999; 79.9 [1.2], 80.0 [1.2], and 80.0 [1.3], respectively). Baseline residual ridge height measured on CBCT was similar (P = .1; 8.8, 9.9, and 9.4 mm, respectively), but implant diameter and length placed in the maxilla differed (P = .03/P < .001; 4.7/11.4 mm, 4.3/8.1 mm, and 4.7/11.8 mm, respectively). Primary implant stability was significantly correlated to CBCT bone density (r = 0.37). Conclusion: Primary and secondary implant stabilities of bicortical fixation did not differ significantly from those of unicortical fixation and indirect sinus elevation. However, use of the bicortical fixation technique is warranted since it is simpler and more economical than indirect sinus elevation; plus, it allows for longer implants than the unicortical fixation while yielding similar secondary implant stability.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help