LOGIN
 
Share Page:
Back

Volume 19 , Issue 5
September/October 2004

Pages 667 - 678


Osseointegration of Dental Implants Complexed with rhBMP-2: A Comparative Histomorphometric and Radiographic Evaluation

Nikitas Sykaras, DDS, PhD/ Ronald D. Woody, DDS/Anthony M. Iacopino, DMD, PhD/R. Gilbert Triplett, DDS, PhD/Martha E. Nunn, DDS, PhD


PMID: 15508982

Purpose: To evaluate the effect of rhBMP-2 on implant osseointegration using histomorphometric and radiographic imaging analyses and determine the diagnostic accuracy of periapical radiographs regarding clinical bone-implant contact levels. Materials and Methods: Hollow-cylinder implants were filled with an absorbable collagen sponge soaked with recombinant human bone morphogenetic protein-2 (rhBMP-2) or left empty and implanted in the mandibles of dogs. Animals were followed for 2, 4, 8, or 12 weeks. At the end of each time interval, the animals were sacrificed and specimens were collected for histomorphometric and radiographic evaluation of the bone-implant contact levels. Results: Both groups exhibited the same mean histologic bone-implant contact on the outer surface of the implant, except for the 4-week group. The radiographic evaluation of bone-implant contact overestimated the actual osseointegration levels by at least 30%, a significant amount. Discussion: The osteoinductive and regenerative potential of rhBMP-2 is of clinical benefit in cases where bone augmentation is indicated and improved levels of osseointegration are expected. Radiographic evaluation has been the most widely employed technique in clinical practice for assessing bone levels around dental implants and comparing changes over time. However, there is a limit to the diagnostic accuracy of conventional radiographs when compared to the data obtained by histologic analysis. Conclusion: Application of rhBMP-2 within the confined boundaries of the hollow chamber of the implant had a limited effect on the osseointegration level along its outer surface, perhaps because of physically restricted diffusion. Radiographic evaluation resulted in the overestimation of bone-implant contact, and poor correlation with the histomorphometric data was found.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help