Effect of Diamondlike Carbon Coating on Reliability of Implant-Supported Crowns

Ronaldo Hirata, DDS, MS, PhD/Lucas Silveira Machado, DDS, MS/Estevam A. Bonfante, PhD/Satoshi Yamaguchi, PhD/Satoshi Imazato, DDS, PhD/Paulo G. Coelho, PhD


PMID: 26252032
DOI: 10.11607/jomi.3750

Purpose: To evaluate the effect of diamondlike carbon (DLC) coating on abutments and/or abutment screws on the reliability, characteristic strength, and Weibull modulus of implant-supported single crowns. Materials and Methods: Seventy-two external hexagon implants (Emfills Implant 4 mm diameter, 10 mm length, Emfills) were divided into four groups (n = 18 each), according to the presence or not of a DLC coating in the abutment and/or abutment screw, as follows: abutment without coating, screw without coating (AwcSwc); abutment without coating with coated screw (AwcSC); abutment coated with noncoated screw (ACSwc), and coated abutment with coated screw (ACSC). Abutments and screws were evaluated with scanning electron microscopy. The specimens were subjected to step-stress accelerated life testing in water. Use-level probability Weibull curves and reliability for a mission of 100,000 cycles at 150 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: For a mission of 100,000 cycles at 150 N, reliability was 0.45 (0.20 to 0.67), 0.12 (0.00 to 0.47), 0.56 (0.17 to 0.82), and 0.44 (0.07 to 0.77) for AwcSwc, AwcSC, ACSwc, and ACSC, respectively. The probability Weibull calculation showed a Weibull modulus (m) of m = 5.50, m = 11.64, m = 16.96, and m = 15.08 and the characteristic strengths (η, which indicates the load at which 63.2% of the specimens of each group fail) of η = 202.67 N, η= 206.64 N, η = 192.54 N, and η = 203.59 N for AwcSwc, AwcSC, ACSwc, and ACSC, respectively. Abutment screw fracture was the chief failure outcome in all groups. Conclusion: Characteristic strength values were not different among groups; neither was reliability. However, an increase in Weibull modulus (indicating low variability of the results) was observed with DLC coating of abutment or screw or both.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help