LOGIN
 
Share Page:
Back

Volume 29 , Issue 6
November/December 2014

Pages 1364–1368


Influence of the Milliamperage Settings on Cone Beam Computed Tomography Imaging for Implant Planning

Taruska Ventorini Vasconcelos, DDS, MS/Frederico Sampaio Neves, DDS, MS/Deborah Queiroz de Freitas, MS, PhD/Paulo Sérgio Flores Campos, MS, PhD/Plauto Christopher Aranha Watanabe, MS, PhD


PMID: 25265127
DOI: 10.11607/jomi.3524

Purpose: To evaluate the influence of the milliamperage settings on cone beam computed tomography (CBCT) images for qualitative and quantitative preoperative implant planning. Materials and Methods: Eight dry mandibles were scanned under different milliamperage values (2, 4, 6.3, 8, 10, 12, and 15 mA) available for selection on the Kodak 9000 CBCT unit. Cross-sectional slices of incisor, canine, premolar, first molar, and second molar regions were analyzed by three oral radiologists. A subjective image quality evaluation of the anatomical structures and an objective evaluation using bone height measurements compared with the real measurements obtained in the mandible were performed. After 30 days, 25% of the sample was reevaluated to obtain the reproducibility of the results. Results: The weighted-kappa coefficient and intraclass correlation coefficient for intra- and interobserver agreement varied between moderate and substantial agreement for the image quality evaluation, and excellent agreement was found for the bone measurements. For the image quality evaluation, the Friedman test showed a negative influence of the milliamperage setting only when the lowest values (2 and 4 mA) were used; for the measurements, one-way analysis of variance with the post hoc Tukey test showed that milliamperage settings did not influence their accuracy. However, images obtained with 6.3 mA were closest to the real measurements. Conclusion: On the basis of this study of dried skulls using CBCT, it was determined that image quality degradation was not significantly improved when the milliamperage setting was increased above 6.3 mA, whereas a milliamperage level below 6.3 mA resulted in degradation of the image quality. Therefore, significant dose reduction can be achieved with diagnostically satisfactory image quality on CBCT exams for implant planning by reducing the milliamperage setting.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help