LOGIN
 
Share Page:
Back

Volume 29 , Issue 3
May/June 2014

Pages 659–666


Implant Treatment in Atrophic Posterior Mandibles: Vertical Regeneration with Block Bone Grafts Versus Implants with 5.5-mm Intrabony Length

David Peñarrocha-Oltra, DDS, MSc, PhD/Amparo Aloy-Prósper, DDS, MSc/Juan Cervera-Ballester, DDS, MSc/Maria Peñarrocha-Diago, DDS, PhD/Luigi Canullo, DDS, PhD/Miguel Peñarrocha-Diago, MD, PhD


PMID: 24818205
DOI: 10.11607/jomi.3262

Purpose: To retrospectively compare the outcomes of implants placed in posterior mandibles vertically regenerated with onlay autogenous block bone grafts and short dental implants. Materials and Methods: Consecutive patients with vertical bone atrophy in edentulous mandibular posterior regions (7 to 8 mm of bone above the inferior alveolar nerve) were treated with either implants placed in regenerated bone using autologous block bone grafts (group 1) or short implants (with 5.5-mm intrabony length) in native bone (group 2) between 2005 and 2010 and followed for 12 months after loading. The procedure used was the established treatment protocol for this type of patient at the Oral Surgery Unit (University of Valencia, Spain) at the time of surgery. All grafts were obtained using piezosurgery. The outcomes assessed were: complications related to the procedure, implant survival, implant success, and peri-implant marginal bone loss. Statistical analysis was done using the Fisher exact test and the Mann-Whitney test. Results: Thirty-seven patients were included, 20 (45 implants) in group 1 and 17 (35 implants) in group 2. In group 1, 13 implants were less than 10 mm long (2 were 7 mm and 11 were 8.5 mm), and 32 were 10 mm or longer; the diameter was 3.6 mm in 6 implants, 4.2 mm in 31, and 5.5 mm in 8. In group 2 all implants were 7 mm long; the diameter measured 4.2 mm in 14 implants and 5.5 mm in 21 implants. Complications related to the block bone grafting procedure were temporary hypoesthesia in one patient, wound dehiscence with graft exposure in three patients, and exposure of the osteosynthesis screw without bone graft exposure in one patient. After 12 months, implant survival rates were 95.6% in group 1 and 97.1 % in group 2; success rates were 91.1% and 97.1%, respectively. The average marginal bone loss was 0.7 ± 1.1 mm in group 1 and 0.6 ± 0.3 mm in group 2. Conclusions: When residual bone height over the mandibular canal is between 7 and 8 mm, short implants (with 5.5-mm intrabony length) might be a preferable treatment option over vertical augmentation, reducing chair time, expense, and morbidity.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help