Systematic Review on Success of Narrow-Diameter Dental Implants

Marc O. Klein, PD Dr Med, Dr Med Dent/Eik Schiegnitz, Dr Med/Bilal Al-Nawas, Prof Dr Med, Dr Med Dent


PMID: 24660189
DOI: 10.11607/jomi.2014suppl.g1.3

Purpose: The aim of this systematic review was to determine the survival and success rates of narrow-diameter implants (NDI) in different clinical indications compared to standard diameter implants. Materials and Methods: Implant diameters were categorized into categories 1 (< 3.0 mm), 2 (3.00 to 3.25 mm), and 3 (3.30 to 3.50 mm). Retro- and prospective studies with more than 10 patients and a follow-up time of 1 year or more were included. Results: A literature search from 1995 to 2012 revealed 10 articles reporting on implant diameters < 3 mm (Category 1), 12 articles reporting on implant diameters 3 to 3.25 mm (Category 2), and 16 articles reporting on implant diameters 3.3 to 3.5 mm (Category 3). The quality of the studies was mostly low with a high risk of bias. Dental implants < 3.0 mm (mini-implants) were one-piece in the edentulous arch and non-loaded frontal region with survival rates between 90.9% and 100%. For dental implants with a diameter between 3.0 and 3.25 mm, most were two-piece implants inserted into narrow tooth gaps without loading and in the frontal region. Survival rates for these implants ranged between 93.8% and 100%. Implants of 3.3 to 3.5 mm were two-piece and were also used in the load-bearing posterior region. Survival rates were between 88.9% and 100%, and success rates ranged between 91.4% and 97.6%. A meta-analysis was conducted for NDI (3.3 to 3.5 mm), which showed no statistically significant difference in implant survival compared to conventional implants with an odds ratio of 1.16 (0.7 to 1.69). Conclusions: Narrow-diameter implants of 3.3 to 3.5 mm are well documented in all indications including load-bearing posterior regions. Smaller implants of 3.0 to 3.25 mm in diameter are well documented only for single-tooth non-load-bearing regions. Mini-implants < 3.0 mm in diameter are only documented for the edentulous arch and single-tooth non-load-bearing regions, and success rates are not available. Long-term follow-up times > 1 year and information on patient specific risk factors (bruxism, restoration type) are also missing.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2022 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help