LOGIN
 
Share Page:
Back

Volume 28 , Issue 6
November/December 2013

Pages e321–e329


Mechanical Comparison of Experimental Conical-Head Abutment Screws with Conventional Flat-Head Abutment Screws for External-Hex and Internal Tri-Channel Implant Connections: An In Vitro Evaluation of Loosening Torque


Abílio Ricciardi Coppedê, DDS, PhD/Adriana Cláudia Lapria Faria, DDS, PhD/Maria da Gloria Chiarello de Mattos, DDS, PhD/Renata Cristina Silveira Rodrigues, DDS, PhD/Jamil Awad Shibli, DDS, PhD/Ricardo Faria Ribeiro, DDS, PhD


PMID: 24278937
DOI: 10.11607/jomi.3029

Purpose: This study compared the loosening torque of experimental conical-head abutment screws to that of conventional flat-head screws of implants with external-hex (EH) and internal tri-channel (IT) connections before and after mechanical loading. Materials and Methods: Forty-four implant/screw/abutment assemblies were divided into four groups: EH/flat-head screw (EH), IT/flat-head screw (IT), EH/conical-head screw (EHCS), and IT/conical-head screw (ITCS). Three assemblies from each group were analyzed in a stereoscopic magnifier and then returned to their respective groups. One assembly was removed from each group and transversely sectioned for optical microscopy analysis. Abutments were tightened at 32 Ncm of torque; after 10 minutes, loosening torque was measured. The same abutments were then retightened with 32 Ncm of torque; after 10 minutes, they were mechanically loaded for 300,000 cycles and loosening torque was again measured. Data were collected and an exploratory analysis was performed. Comparisons were made by orthogonal contrasts using a linear mixed effects model (random and fixed effects). Results: Comparisons before mechanical cycling showed significant differences between groups except for EH vs IT and EHCS vs ITCS. After mechanical cycling, only the comparisons EH vs IT and EHCS vs ITCS showed no significant differences. Considering the same group, before and after mechanical cycling, all comparisons showed significant differences. Conclusions: The shape of the abutment screw head significantly influenced loosening torque: conical-head screws showed higher loosening torque values than conventional flat-head screws before and after loading. The implant/abutment connection design exerted no significant influence on loosening torque.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help