Vertical Fracture and Marginal Bone Loss of Internal-Connection Implants: A Finite Element Analysis


Ryo Jimbo, DDS, PhD/Anders Halldin, MS/Martin Janda, DDS, PhD/Ann Wennerberg, DDS, PhD/Stefan Vandeweghe, DDS, PhD


PMID: 23869374
DOI: 10.11607/jomi.3052

Purpose: Marginal bone loss around implants is of great concern, and its cause may be multifactorial. Recently, clinical cases presenting marginal bone loss, in most cases accompanied by vertical fracture of internal-connection implants in the buccolingual direction, have been reported, in which unfavorable stress distribution is one possible cause of marginal bone resorption. The purpose of the current study was to characterize this type of marginal bone loss and implant fracture by conducting a finite element analysis (FEA). Materials and Methods: Clinical and radiographic evaluations showed that the prostheses of all reported cases had implant-level setups and were directly screwed to the internal implants. Intriguingly, all vertical fractures reported were in the buccolingual direction. Therefore, to characterize the specific implant fractures, FEA was conducted with misfit models created for two different setups, abutment-level and implant-level, both with screw-retained prostheses. The models were subjected to initial misfits of 0 μm (representing perfect fit), 50 μm, 100 μm, 150 μm, or 200 μm, and vertical loading was then applied. Results: FEA revealed that, for the implant-level setup, excessive stress at the neck of the implant gradually increased in the buccolingual direction as the misfit increased. This result was not seen for the abutment-level setup. A broad maximum stress distribution was evident for the implant-level setup but not for the abutment-level setup. Conclusion: Broad distribution of excessive stress in the FEA correlated to the clinical cases, and marginal bone loss in these cases may be associated with mechanical alterations. To avoid unnecessary complications, selection of an abutment-level setup is strongly suggested.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help