Volume 28 , Issue 2
March/April 2013

Pages e88e97


Selection of Optimal Expansion Angle and Length of an Expandable Implant in the Osteoporotic Mandible: A Three-Dimensional Finite Element Analysis


Jian-rui Xiao, DDS/Liang Kong, DDS/Yu-xuan Chen, DDS/Xiao-xian Han, MD/Yong-feng Li, DDS


PMID: 23527373
DOI: 10.11607/jomi.2368

Purpose: To identify from a biomechanical point of view the optimal parameters for an expandable implant in the osteoporotic mandible, a three-dimensional finite element model (FEM) of an expandable implant was created with variations in expansion angle and expansion length. Material and Methods: FEMs of osteoporotic posterior mandibular segments with an expandable implant were created. An axial load of 100 N and a buccolingual load of 30 N were applied to the implant. The expansion angle ranged from 0 to 4 degrees, and the expansion length ratio ranged from 1/6 to 5/6. The maximum equivalent stress (max EQV stress) in jawbone and the implant-abutment complex and the maximum displacement in the implantabutment complex were evaluated. Results: With changes in the expansion angle and expansion length ratio, the max EQV stress in cortical and cancellous bone increased by 12.4% and 73.9%, respectively, under axial loading, respectively, and by 38.6% and 69.1%, respectively, under buccolingual loading. The max EQV stress in the implant-abutment complex increased by 65.3% and 160% under axial and buccolingual loading, respectively. Maximum displacement in the implant-abutment complex increased by 3.66% and 19.73% under axial and buccolingual loading, respectively. Conclusion: Expansion angles and the expansion length ratio favored stress distribution in jawbone under axial and buccolingual loads, respectively. An expansion angle between 1.5 and 2.5 degrees and an expansion length ratio between 2/6 and 3/6 provided optimal biomechanical properties for an expandable implant in the osteoporotic mandible. Int J Oral Maxillofac Implants 2013;28:e88e97. doi: 10.11607/jomi.2368


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help