Dental Implants with Conical Implant-Abutment Interface: Influence of the Conical Angle Difference on the Mechanical Behavior of the Implant


Josu Aguirrebeitia, PhD/Mikel Abasolo, PhD/Javier Vallejo, PhD/Ruben Ansola, PhD


PMID: 23527371
DOI: 10.11607/jomi.2775

Purpose: Misfit in the conical implant-abutment interface plays an important role on the mechanical behavior of the implant when masticatory forces are applied. The origin of the misfit adopted in this work is a conical angle difference between implant and abutment, which can be due to a combination of design decisions and manufacturing tolerances. The goal of this work was to investigate the effects of the implant-abutment conical angle difference in the following mechanical features: interfacial microgap, preload loss on the bolt, stress level in the bone, and abutment removal force and/or torque. Materials and Methods: A simplified three-dimensional nonlinear monoparametric finite element model of an OsseoSpeed TX 4.5 S 9-mm implant (Astra Tech) with a tapered implant-abutment interface was built to evaluate the variability of the mechanical features cited above with the conical angle difference, keeping constant the overall geometry, load and boundary conditions, material properties, frictional behavior, and mesh structure. Results: As the conical angle difference increased, the following effects were observed: the microgap decreased and remained almost constant for values over a given positive angle difference, the stress level in the bone increased sensitively, the removal force and/or torque needed to separate the abutment from the implant varied slightly, and the bolt preload loss increased. Conclusions: In light of the results provided, the conical angle difference in the implant-abutment interface had a significant influence on the overall mechanical behavior of the implant. Among the four mechanical features considered, the interfacial microgap and the bone stress were demonstrated to be the most sensitive to the conical angle difference, and therefore the most relevant when selecting an optimum value in the design process of a conical interface. Int J Oral Maxillofac Implants 2013;28:e72e82. doi: 10.11607/jomi.2775


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help