Evaluation of Retention of Cemented Laser-Sintered Crowns on Unmodified Straight Narrow Implant Abutments

Mehmet Ali Kilicarslan, DDS, PhD/Pelin Ozkan, DDS, PhD


PMID: 23527338
DOI: 10.11607/jomi.2635

Purpose: A common problem with cemented crowns is inadequate retention at the crown-abutment interface. The aim of this study was to compare the retention of new laser-sintered cobalt-chromium alloy crowns to the retention of cobalt-chromium alloy crowns fabricated with a traditional casting technique with and without an alloy primer. Materials and Methods: Twenty-four metallic crowns per casting technique were fabricated, and surface roughness values were recorded with a profilometer. Alloy primer was applied to half the specimens, and all crowns were luted with resin cement. After 24 hours, specimens were subjected to tensile force application with a universal testing machine. The effect of the cement amount was evaluated with an analytic balance. The results were compared using the Kruskal-Wallis multiple-comparison test. The Spearman correlation was used to determine correlations between crown retention and cement weight. Results: The laser-sintered crowns (2.72 μm) were rougher than conventionally cast crowns. The mean load to failure values were as follows: 455.10 192.69 Ncm for conventional crowns, 565.52 112.87 Ncm for conventional crowns with alloy primer, 534.78 130.15 Ncm for laser-sintered crowns, and 678.60 212.83 Ncm for laser-sintered crowns with alloy primer. Laser-sintered crowns (10.10 2.15 mg) showed a significant difference in terms of cement weight compared with cast crowns. In addition, negative correlations were found for retention and cement weight between all groups, except for the laser-sintered group without alloy primer. Conclusions: Retentive forces were significantly higher for laser-sintered crowns than for conventionally cast crowns. An increase in the surface roughness and the application of alloy primers led to an increase in the adhesive bonding of resin cements to metal alloys. It was concluded that a reduction in cement weight improved retention. Int J Oral Maxillofac Implants 2013;28:381387. doi: 10.11607/jomi.2635


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help