Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy

Zerrin Fidan Akalin, PhD, DDS/Yasemin Kulak Ozkan, PhD, DDS/Ahmet Ekerim, PhD


PMID: 23377060
DOI: 10.11607/jomi.2070

Purpose: The effects of implant angulation, impression material, and variation in width of the arch curvature on transfer models were evaluated. Materials and Methods: Three edentulous maxillary epoxy resin models were fabricated, and six internal-connection implant analogs were placed in different locations and different angulations in each model. In the first model, implants were positioned in the canine, first premolar, and first molar regions, and all analogs were positioned parallel to each other and perpendicular to the horizontal crestal plane (parallel model). In the second model, analogs were positioned in same regions (canine, first premolar, and first molar), but three of them were positioned with 10-degree buccal angulations (versus the horizontal crestal plane) (angular model). In the third model, analogs were inserted in the lateral incisor, canine, and second molar regions and parallel to each other (wide-arch model). Eighteen impressions of each model were made with each of the three materials—condensation silicone, polyvinyl siloxane, and polyether—and impressions were poured and kept at room temperature for 24 hours. They were then observed under a toolmaker’s microscope, with epoxy resin models of each group used as references. Distance deformations between implants in each model in the x- and y-axes were recorded separately. Implant angulation deformations were recorded in the x-z plane. Statistical evaluations were performed with analysis of variance and the least significant difference post hoc test. Results: Angular model measurements showed the greatest deformation values (P < .05). All impression materials showed deformation, and the polyether impression models showed statistically significantly less deformation in angular measurements (P < .05). Conclusions: The models with implants placed parallel to each other exhibited greater accuracy than a model with implants placed at angles to each other. Int J Oral Maxillofac Implants 2013;28:149–157. doi: 10.11607/jomi.2070

Key words: implant angulation, impression accuracy, impression material, impression technique


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help