LOGIN
 
Share Page:
Back

Volume 27 , Issue 6
November/December 2012

Pages 14221428


The Effect of Impression Technique and Implant Angulation on the Impression Accuracy of External- and Internal-Connection Implants

Pavlos Mpikos, DDS, PhD/Nikolaos Kafantaris, DDS, PhD/Dimitrios Tortopidis, DDS, PhD/Christos Galanis, PhD/George Kaisarlis, PhD/Petros Koidis, DDS, MSc, PhD


PMID: 23189292

Purpose: The purpose of this in vitro study was to investigate the effect of impression technique and implant angulation on the impression accuracy of external- and internal-connection implants using a novel experimental device. Materials and Methods: An experimental device was designed and fabricated to make in vitro impressions by means of open- and closed-tray techniques. Impressions of eight implants with two different connections (four external-hex and four internal-hex) at three angulations (0, 15, and 25 degrees) were made using a medium-consistency polyether material. Evaluation of implant impression accuracy was carried out by directly measuring the difference in coordinate values between the implant body/impression coping positioned on the base and the impression coping/laboratory analog positioned in the impression using a touch-probe coordinate measuring machine. Experimental data were analyzed by two-way analysis of variance. The significance level of all hypothesis testing procedures was set at P < .05. Results: The results showed that: (1) for implants with external connections, impression accuracy is not significantly affected by the impression technique, implant angulation, or their interaction; and (2) for implants with internal connections, impression accuracy is significantly affected only by implant angulation: Impression inaccuracy was greater at the 25-degree implant angulation. Conclusions: Within the limitations of this in vitro study, the open- and closed-tray techniques had no effect on the accuracy of multiple implant impressions. The interaction between impression technique and implant angulation was also not significant. However, implant angulation significantly affected the impression accuracy when implants with internal connections were used. Int J Oral Maxillofac Implants 2012;27:14221428

Key words: external-connection implants, implant angulation, impression accuracy, impressions, internalconnection implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help