LOGIN
 
Share Page:
Back

Volume 18 , Issue 6
November/December 2003

Pages 835–847


Randomized Multicenter Comparison of 2 IMZ and 4 TPS Screw Implants Supporting Bar-Retained Overdentures in 425 Edentulous Mandibles

Jochen Mau, Dr rer nat/Alexandra Behneke, Dr med dent/Nikolaus Behneke, Dr med dent/Claus Udo Fritzemeier, Dr med, Dr med dent/German Gomez-Roman, Dr med dent/Bernd d’Hoedt, Dr med dent/Hubertus Spiekermann, Dr med, Dr med dent/Volker Strunz, Dr med, Dr med dent/Mei Yong, MPH


PMID: 14696659

Purpose: Two treatment concepts for implant-supported bar retention of mandibular overdentures—2 intramobile cylinder (IMZ) implants and a Dolder bar and 4 titanium plasma-sprayed (TPS) screw implants and an angulated bar—were compared in a randomized controlled clinical trial with respect to postprosthetic efficacy and safety. Materials and Methods: Four hundred twenty-five patients with edentulous mandibles were enrolled; 212 were randomized to TPS implants (control group) and 213 to IMZ implants (test group). Endpoints were occurrences of postprosthetic integration deficiency (ID), functional deficiency (FD), and complications. The trial was sized to detect a 10% difference in 5-year ID-free postprosthetic system lifetime with a power of 80%. Results: With 340 protocol-completed cases, the trial achieved its predetermined power. The 2 systems did not show statistically significant differences in occurrences of postprosthetic ID and FD; 5-year occurrence-free postprosthetic system lifetime probabilities were estimated as 42.5% with IMZ and 42.8% with TPS, for ID; and as 82.6% with IMZ and 87.2% with TPS, for FD. However, at 3 to 6 months after surgery, mean Periotest values were significantly higher (P = .0001 without adjustment) with IMZ implants (5.6, SD 4.2) than with TPS implants (0.8, SD 4.3). TPS implants showed a higher incidence of inflammation and recession, while IMZ implants had a higher incidence of implant fracture after functional loading. Discussion: The system- wise approach overcomes potential bias with implant-wise analyses. A combination of radiographic and clinical criteria distinguishes between desirable integration and functional anchorage. The in situ survival rates at 5 years in this study (95% for IMZ, 92% for TPS) match rates reported in the literature. Conclusion: This study demonstrated equivalent efficacy of 2 IMZ cylinders and 4 TPS screws in implant-supported, bar-retained mandibular overdentures and indicated a higher rate of complications with the TPS screw implants. INT J ORAL MAXILLOFAC IMPLANTS 2003;18:835–847


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help