Comparison of the Effects of Phosphate-Coated and Sandblasted Acid-Etched Titanium Implants on Osseointegration: A Microcomputed Tomographic Examination in the Canine Model

Stephen S. Walker, DDS/Elias D. Kontogiorgos, DDS, PhD/Paul C. Dechow, PhD/David G. Kerns, DMD, MS/Carl J. Nelson, PhD/Lynne A. Opperman, PhD


PMID: 23057019

Purpose: This study tested the effects of phosphate treatment of titanium on bone volume fraction (BV/TV) at 30 to 60 μm from the implant surface using microcomputed tomography to analyze the mineralized tissue. Materials and Methods: Electrolytically phosphated (50/100 volts [T1/T2]) or nonphosphated 3.3- 8-mm titanium implants (C) with sandblasted acid-etched surfaces were placed in 40 mandibular sites in five foxhounds 6 weeks after the extraction of the premolars. After 4 weeks, the animals were sacrificed, and BV/TV was analyzed using microcomputed tomography. Results: The mean BV/TV ( standard deviation) of the control implants was 31.4% 15.3% (range, 10.9% to 55.3%). For the T1 implants, a mean BV/TV of 38.4% 10.7% (range, 21.6% to 57.3%) was seen, and for T2 implants, the mean BV/TV was 40.3% 15.1% (range, 16.5% to 61.1%). Mean BV/TV values for the groups were not significantly different. For all groups (C, T1, and T2), there were no significant differences in BV/TV at the most coronal slices. For all groups, there was a positive slope showing more bone apposition as the slices moved from coronal to apical. The T2 group showed significantly increased mineralized tissue moving from the coronal to the apical section of the implant, compared to the control and T1 implants. Conclusion: Access to better blood supply and bone cells from the marrow spaces in the apical regions may lead to a better trabecular bone response. Increased mineralized tissue apposition may allow for accelerated loading and more predictable implant placement in sites with poorquality bone or patients with compromised bone healing. Int J Oral Maxillofac Implants 2012;27:10691080

Key words: acid etching, dental implant, microcomputed tomography, osseointegration, phosphate, surface properties, titanium


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help