LOGIN
 
Share Page:
Back

Volume 18 , Issue 5
September/October 2003

Pages 691–696


Porous Hydroxyapatite for Grafting the Maxillary Sinus in Sheep: Comparative Pullout Study of Dental Implants

Robert Haas, DMD, MD/Monika Baron, DMD, MD/Werner Zechner, DMD, MD/Georg Mailath-Pokorny, DMD, MD


PMID: 14579957

Purpose: In this experimental study, dental implants placed after maxillary sinus grafting with either porous hydroxyapatite (HA) (Interpore 200) or autogenous bone were examined for their mechanical stress tolerance. Materials and Methods: A total of 54 titanium plasma flame–sprayed cylindric implants were placed in the lateral sinus wall bilaterally of 27 mountain sheep. The bony sinuses were opened through an extraoral approach. Eighteen sinuses were grafted with porous HA, and another 18 were grafted with cancellous bone from the iliac crest. Eighteen non-grafted sinuses were used as controls. In the same operation, 2 cylindric implants were placed in each of the sinuses. One implant of each sinus was tested for mechanical strength of the bone-implant interface at 12, 16, and 26 weeks using pullout force. Results: The mean pullout force was 259.3 N in the control group, 356.7 N in the autogenous bone group, and 376 N in the HA group. Pooled data for the grafted sites showed the pullout force to be significantly higher than in the empty control sites (P = .02). The pullout force increased significantly with ongoing healing time (P = .02), but there was considerable variation within the groups. While the force remained more or less constant throughout the follow-up time in the controls (248 N at week 12 to 276 N at week 26), it increased dramatically in the group augmented with autogenous bone (223.8 N at week 12 to 523.16 N at week 26). The pullout force was initially highest in the HA group (302.3 N at week 12) and increased to 423.5 N at 26 weeks, but it did not reach the levels recorded in the autografted group. Discussion and Conclusion: Mechanical tests of bone-toimplant contact in a sheep model showed that HA for 1-stage sinus floor elevation significantly increased the pullout force versus ungrafted sinuses, although it was less than that found with autogenous bone after 26 weeks. INT J ORAL MAXILLOFAC IMPLANTS 2003;18:691–696


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help