Immediately Loaded Mandibular Fixed Implant Prostheses Using the All-On-Four Protocol: A Report of 183 Consecutively Treated Patients with 1 Year of Function in Definitive Prostheses

Daniel F. Galindo, DDS/Caesar C. Butura, DDS


PMID: 22616057

Purpose: The purpose of this study was to evaluate a specific protocol using four implants to support immediately loaded fixed prostheses to restore edentulous and partially edentulous mandibles and report on the outcome after 1 year of function with the definitive prostheses. Materials and Methods: A retrospective study was conducted of all patients who were treated between June 2008 and December 2010 with fixed prostheses that were loaded immediately after placement of implants. The provisional prostheses were later replaced with computer-aided design/computer-assisted manufacture titanium frames supporting acrylic resin and denture teeth in the definitive prosthesis. All patients were followed for a minimum of 12 months and were assessed for implant survival and prosthetic performance, with descriptive statistics utilized to demonstrate results. Results: One hundred eighty-three consecutive patients received immediately loaded axial and tilted implants according to the defined protocol. One implant failed, resulting in a 99.86% implant success rate. There were two catastrophic prosthetic failures (fracture of the titanium framework), for a 98.9% prosthetic success rate. Three patients (1.6%) presented with fracture of a prosthetic mandibular incisor tooth. No prosthetic screw loosening or fractures were seen. Radiographic evaluation revealed no major bone loss around dental implants. Conclusions: Based on this retrospective study, the following conclusions can be drawn: (1) this technique appears to provide a highly predictable implant performance; (2) it is necessary to critically evaluate framework design, especially around the connectors for cantilever extensions around the most distal implants; and (3) minor complications related to acrylic resin tooth fracture may be anticipated during the early phases of prosthetic treatment. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:628633.

Key words: dental implants, immediate loading, implant-supported fixed prosthesis, tilted implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help