A Novel Device for Resonance Frequency Assessment of One-Piece Implants

Eran Gabay, DMD, PhD/Omer Cohen, DMD, PhD/Eli E. Machtei, DMD


PMID: 22616044

Purpose: Immediate loading and/or restoration of dental implants requires the assessment of implant stability, which is best performed by resonance frequency analysis (RFA) prior to loading. One-piece dental implants are usually used for immediate loading, but there is currently no available reliable method to assess the primary stability of one-piece dental implants. Therefore, this study sought to validate a novel device designed for RFA measurements of one-piece implants. Material and Methods: Thirty (3.75 × 13 mm) internal-hex implants (Seven, MIS) were divided into two groups; 15 were placed in an acrylic glass block and 15 were placed in fresh porcine jawbone using 30 N/cm2 of insertion torque. Implant stability quotient (ISQ) values were measured using the Osstell Mentor device; then, a new external fixation device was attached to the implant abutment with a 10-mm arm extending from the implant to an internal-hex ring at its proximal end. ISQ values were measured at the implant’s internal hex and at the internal hex of the device, and the damping ratio was calculated. The measurements were repeated with 15 (3 × 13 mm) one-piece implants (UNO, MIS) attached to the same device. Results: The damping ratio between the implant and the proximal device was 23.6% ± 4% in acrylic glass (50.1 ± 1.7 ISQ and 38.2 ± 1.8 ISQ, respectively) and 23.1% ± 3% in porcine bone (74.9 ± 2.8 ISQ and 57.5 ± 0.5 ISQ, respectively). ISQ values determined by the device on one-piece and two-piece implants were similar (57.4 ± 0.9 and 57.5 ± 0.5, respectively). Conclusion: With the present validation of this external fixation device for the measurements of implant stability using RFA, it is now possible to measure primary stability of any one-piece implant system, obviating the need for custom-made Osstell adaptors. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:523–527. Key words: damping ratio, implant stability quotient, one-piece implants, primary stability, resonance frequency analysis


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help