In Vitro Validation of a Novel Diagnostic Device for Intraoperative Determination of Alveolar Bone Quality

Tim Krafft, PD Dr Med, Dr Med Dent/Werner Winter, Dr-Ing/Manfred Wichmann, Prof Dr Med Dent/Matthias Karl, PD Dr, Med Dent


PMID: 22442770

Purpose: Current methods for the evaluation of alveolar bone quality and dental implant stability have been shown to provide inconsistent results. The aim of this investigation was to validate a novel diagnostic device (BoneProbe) for the objective classification of alveolar bone during dental implant surgery. Materials and Methods: A metal cylinder (diameter, 3.5 mm) split into six segments was used as a sensor that could be positioned in implant sockets and expanded while the force needed to expand the site was recorded. Simulating all surgical steps, implants were placed into polyurethane foam materials (n = 100 implants) and human cadaver bone (n = 110 implants). Bone quality (cortical bone thickness, trabecular bone density, drilling resistance, implant insertion torque, compressive testing) and primary implant stability (Osstell, Periotest) were evaluated as reference data. Results: In polyurethane foam, significant correlations between all parameters (Pearson correlation coefficients) and a significant influence of the different polyurethane foam materials on all measurement results (multiple analysis of variance with Pillai trace) were found. In general, in human cadaver bone, weaker correlations between the different measurement techniques were seen (Pearson product-moment correlation). With the exception of compressive testing and radiographic assessment of trabecular bone density, all methods were able to differentiate between mandibular and maxillary bone. Conclusions: Based on these in vitro results, it appears that intraoperative testing of alveolar bone allows for a reproducible classification of bone quality. Because the proposed system is independent of any specific implant design, this device could be used for establishing a universally valid bone classification system. Int J Oral Maxillofac Implants 2012;27:318328

Key words: bone density, bone quality, compressive testing, implant stability


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help