Bone-Implant Interface with Simulated Insertion Stress Around an Immediately Loaded Dental Implant in the Anterior Maxilla: A Three-Dimensional Finite Element Analysis

Joon-Seok Lee, DDS, MSD, PhD/In-Ho Cho, DDS, MSD, PhD/Yung-Soo Kim, DDS, MSD, PhD/Seong-Joo Heo, DDS, MSD, PhD/Ho-Beom Kwon, DDS, MSD, PhD/Young-Jun Lim, DDS, MSD, PhD


PMID: 22442767

Purpose: The purpose of the present study was to investigate the stress distribution around the bone-implant interface and the effect of the length of an immediately loaded implant in the anterior maxilla using a finite element model with simulated loading stresses. Materials and Methods: Four-mm-diameter external-hex implants with different lengths (8.5, 10.0, 11.5, 13.0, and 15.0 mm) were used in this study. The anterior maxilla was assumed to be D3 bone quality. All of the material was assumed to be homogenous, isotropic, and linearly elastic. Average bone deformation during implant placement was calculated through the simulation process, and using this, insertion stress was created. The bone-implant interface was constructed using a contact element to simulate a nonosseointegrated condition. Then, 176 N of static force was applied at the middle of the palatoincisal line angle of the abutment at a 120-degree angle to the long axis of the abutment. The von Mises stresses were measured at intervals of 0.25 mm along the bone-implant interface. Results: Prior to loading, the stresses were evenly distributed around the implant and highly concentrated in the cortical area. When the load was applied, von Mises stresses were concentrated in the cortical bone of the implant neck area. More favorable stress distribution was seen with increasing implant length. However, when the implant length reached 15.0 mm, the stresses increased. Conclusions: In the maxilla, when immediate loading is applied after implant placement, 11.5- and 13.0-mm-long single implants showed more favorable stress patterns than the others analyzed. If implants longer than 15.0 mm are used in immediate loading, sufficient bone volume in the recipient site should be considered an important factor. Int J Oral Maxillofac Implants 2012;27:295302

Key words: anterior maxilla, dental implants, finite element analysis, immediate loading, insertion stress


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2017 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help