Volume 27 , Issue 1
January/February 2012

Pages 162172


Stability and Marginal Bone Loss with Three Types of Early Loaded Implants During the First Year After Loading

Argir Liaje, PhD/Yasemin Kulak Ozkan, PhD/Yasar Ozkan, PhD/Burcin Vanlioglu, PhD


PMID: 22299093

Purpose: To determine the change in stability of three different implant systems using resonance frequency analysis (RFA) and to correlate RFA measurements with factors related to implant design, length, and diameter, patient gender, and dental arch. Clinical and radiologic evaluations were performed up to 1 year after loading. Materials and Methods: Three different types of implants from three different manufacturers were inserted in the posterior maxilla and mandible. RFA measurements were performed at implant placement and weekly up to 8 weeks postoperatively and were compared with respect to implant type, length, and diameter and dental arch. The implants were loaded after 8 weeks. All implants were examined radiographically at baseline and at 6 and 12 months. Plaque Index, Sulcus Bleeding Index, peri-implant probing depths, and marginal bone loss were recorded. Repeated-measurements analysis of variance, twotailed mixed-model analysis of variance, the Least Significant Differences and Mann-Whitney U tests were used for statistical analyses. Results: All the groups showed high stability values at all time points (above 71). There were statistically significant differences between groups at all time points except 1 and 2 weeks. Mandibular implants showed statistically higher stability values than maxillary implants. Wide implants showed statistically higher stability values than narrow implants. Mean marginal bone loss was 0.22 0.47 mm after 1 year. Conclusions: All three implant systems showed clinically acceptable stability values prior to early loading. The success rates and bone loss were similar to the values reported in the literature. Int J Oral Maxillofac Implants 2012;27:162172

Key words: early loading, implants, implant stability, resonance frequency analysis


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help