LOGIN
 
Share Page:
Back

Volume 27 , Issue 1
January/February 2012

Pages 29-35


Digitizing Implant Position Locators on Master Casts: Comparison of a Noncontact Scanner and a Contact-Probe Scanner

Stefan Holst, Dr med dent, PhD/Anna Persson, PhD/Manfred Wichmann, Dr med dent, PhD/Matthias Karl, Dr med dent, PhD


PMID: 22299075

Purpose: Although several investigations of the fit of computer-aided design/computer-assisted manufactured implant restorations have been reported in the literature, very limited information is available on the accuracy of dental scanners for surface data acquisition. The objective of this research project was to investigate the accuracy and repeatability of a three-dimensional noncontact laser scanning system based on conoscopic holography recording the spatial orientation of an implant in vitro. Materials and Methods: One master cast containing five nonparallel implant replicas with scan abutments (implant position locator [IPL], Nobel Biocare) was repeatedly digitized by two commercially available dental scanners and an industrial highprecision coordinate measuring machine as a reference. Repeated measurements of the center point and vector analysis were applied to determine the accuracy and repeatability of IPL orientation. The Wilcoxon signed rank test modified for equivalence was applied to determine whether the systems were equally accurate based on given threshold limits of 0.010, 0.005, and 0.001 mm. Results: All between-system tests identified significant differences, although most differences were very small in absolute terms. Tests for equivalence based on difference windows were exploratorily significant for 0.010 and 0.005 mm. Conclusion: Conoscopic holography scan technology is a valid option to supplement dental touch-probe scanners for laboratory digitization of implant master casts. Int J Oral Maxillofac Implants 2012;27:2935

Key words: accuracy testing, computer-aided design/computer-assisted manufacture, implant position, laser scanning, scan abutment


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help