Bone Adaptation Induced by Non–Passively Fitting Implant Superstructures: A Finite Element Analysis Based on In Vivo Strain Measurements

Werner Winter, Dr-Ing/Thomas D. Taylor, DDS, MSD/Matthias Karl, Priv-Doz, Dr Med Dent


PMID: 22167435

Purpose: Stress caused by a non–passively fitting implant superstructure may induce bone adaptation, thereby changing the magnitude of static implant loading. Materials and Methods: In a previous investigation, repeated in vivo strain measurements were conducted on an implant-supported bar to evaluate changes in the magnitude of misfit resulting from bone remodeling processes. Both maximum (445 µm/m) and minimum (383 µm/m) strain values were simulated using a three-dimensional finite element model. The horizontal misfit needed to simulate experimentally determined strain values and the resulting stresses occurring in the restoration and the bone were quantified as von Mises equivalent stress. Additionally, different stages of osseointegration were modeled by altering the elastic modulus of bone immediately surrounding the implants. Results: To simulate the maximum strain value, a horizontal misfit of 83.3 µm had to be introduced, whereas the minimum strain value could be simulated via a horizontal misfit of 71.5 µm. Maximum misfit caused stress magnitudes of 105 MPa in cortical bone and 5.3 MPa in trabecular bone. Minimum misfit caused stress magnitudes of 90 MPa in cortical bone and 4.6 MPa in trabecular bone. The difference between maximum and minimum horizontal misfit was 12 µm and led to a reduction in maximum stress levels of 15 MPa in cortical bone and 0.7 MPa in trabecular bone. Progressing osseointegration affected the stress situation of the supporting implants. Conclusions: Within the limitations of this investigation, it can be concluded that bone adaptation may lead to implant site displacement in the range of several micrometers. Early fixation of non–passively fitting superstructures on implants may lead to greater passivity of fit. Int J Oral Maxillofac Implants 2011;26:1288–1295

Key words: bone remodeling, finite element analysis, loading protocol, passive fit, static implant loading, strain gauge


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help