PMID: 22167428

Purpose: To evaluate the effects on bone of forced insertion of self-tapping orthodontic mini-implants and thus obtain biomechanical data to develop insertion protocols and optimize drills for implant site preparation. Materials and Methods: After implant site preparation, 39 orthodontic mini-implants (OMI), 1.6 7.5 mm each, were inserted into the hard bone of sheep mandible; 24 were placed with a 1-mm bone drill and 15 were placed with a standard-diameter (1.2-mm) drill. Removal torque was measured immediately (group A) and 8 weeks after insertion (group B). Eight OMIs (group C) were removed from the mandible in block sections of appropriate size for microcomputed tomographic morphometric and morphologic analyses. Results: All OMIs were placed without complications, with mean insertion torque of 17.625 ( 1.71) Ncm (test groups) and 17.70 ( 1.41) (control groups) and were stable at reentry. Group A implants showed a reduction in removal torque of 5.66%, while in group B, removal torque was reduced by 43.25%. In the control groups (ie, OMIs placed with a 1.2-mm drill), removal torque immediately after placement was reduced by 5.64%, and 8 weeks after insertion, removal torque had declined by 18.2%. Microcomputed tomographic bone morphometric analysis for both test and control groups showed that bone-implant contact was lower than expected in cortical bone 8 weeks after insertion. Morphologic analysis revealed cavities in the cortical bone close to the surface and microcalli in soft bone. Cavities in the cortical bone may have been caused by bone trauma during insertion. Conclusions: The use of a narrow drill for site preparation increased orthodontic screw insertion torque, but it also damaged the bone and decreased removal torque. Standard histologic examination may clarify whether cavities in hard bone are actually signs of bone resorption that results from the activation of remodeling. Int J Oral Maxillofac Implants 2011;26:12331240

Key words: anchorage, bone, bone biomechanics, microcomputed tomography, mini-implants, orthodontic implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help