LOGIN
 
Share Page:
Back

Volume 18 , Issue 4
July/August 2003

Pages 578581


Evaluation of Bone Thickness in the Anterior Hard Palate Relative to Midsagittal Orthodontic Implants

Brent Henriksen, DDS/Bruce Bavitz, DMD/Brad Kelly, DDS/Stanton D. Harn, PhD


PMID: 12939012

Purpose: The Straumann Orthosystem (Institut Straumann, Waldenburg, Switzerland) describes a technique that involves placement of titanium implants (4 or 6 mm long and 3.3 mm in diameter) into the midsagittal hard palate for orthodontic anchorage. The aim of this study was to determine the quantity of bone in the midline of the anterior hard palate, and specifically the thickness inferior to the incisive canal. Materials and Methods: Twenty-five dry skulls were radiographed with a standardized cephalometric technique. The vertical thickness of the midsagittal palate was then measured to the nearest tenth of a millimeter. Next, gutta-percha was injected into the incisive canal, and the radiograph was repeated. The bone thicknesses were then measured from the inferior hard palate to the most inferior part of the radiopaque canal. This is defined as the actual bone available for the implant without violating the canal. Results: The measurements have shown that an average of 8.6 1.3 mm of bone is theoretically available for the implant. However, considering the canal (where only bone thickness inferior to it is utilized and measured), only 4.3 1.6 mm of bone exists. The canal itself averaged 2.5 0.6 mm in diameter. Discussion: Prior studies have overestimated the amount of bone available for implants in the median hard palate. The main reason for this is that the incisive canal is not well visualized on cephalometric radiographs of live patients. Conclusion: This study supports the continued use of implants, as approximately 50% of skulls still had the requisite minimum 4 mm of bone inferior to the incisive canal for maximum osseointegration with the 4-mm implants. However, 6- mm implants should be used with caution. (INT J ORAL MAXILLOFAC IMPLANTS 2003;18:578581)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help