A Comparison of 3 Different Endosseous Nonsubmerged Implants in Edentulous Mandibles: A Clinical Report

Anne-Karine Røynesdal, DDS, Eirik Ambjørnsen, DDS, PhD, Hans R. Haanæs, DDS, MD, PhD


PMID: 10453670

The purpose of this prospective clinical study was to investigate the outcome of 3 different types of endosseous, nonsubmerged implants in the anterior part of the mandible. Fourteen older edentulous patients, 10 females and 4 males, were included. All participants received 3 different types of endosseous implants in the anterior mandible: 1 titanium plasma-sprayed cylindric implant (4 mm in diameter), 1 titanium cylindric implant with hydroxyapatite (HA) coating (4 mm in diameter), and 1 standard threaded titanium implant (3.75 mm in diameter). The 3 types of implants were originally designed to be placed in a 2-step surgical procedure. However, at this stage all implants were simultaneously provided with a temporary abutment that penetrated the mucosa. Three months later the temporary abutments were replaced by ball abutments, which were connected to an overdenture. At 12, 24, and 36 months after surgery, marginal bone resorption and Periotest values were recorded. Two patients died within the 2 first postoperative years. Five of 42 implants (11.9%) failed to osseointegrate. After 3 years, marginal bone resorption around titanium plasma-sprayed implants was significantly greater than that seen around both HA-coated and threaded titanium implants. Threaded titanium implants also had significantly better scores for marginal bone resorption than the HA-coated implants. Periotest values for HA-coated cylinders were significantly lower than test values for the other implants after 3 years (P < .05). The conclusion from this investigation is that nonsubmerged implants showed impaired prognoses compared to implants placed according to the 2-stage concept. Marginal bone resorption around titanium plasma-sprayed cylindric implants was clearly increased compared to the 2 other implant systems. Periotest values for HA-coated cylindric implants were superior to titanium plasma-sprayed and pure titanium implant surfaces. (Int J Oral Maxillofac Implants 1999;14:543–548) Key words: hydroxyapatite-coated implants, marginal bone resorption, nonsubmerged implants, overdentures, titanium plasma spray–coated implants, titanium threaded implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help