Ligature-Induced Peri-implant Bone Loss Around Loaded Zirconia and Titanium Implants

Stefan Roehling, DDS/Michael Gahlert, DDS, PhD/Simone Janner, DDS/Bo Meng, DDS/Henriette Woelfler, PhD/David L. Cochran, BA, MS, DDS, PhD, MMS


PMID: 30716147
DOI: 10.11607/jomi.7015

Purpose: To radiographically investigate ligature-induced peri-implant bone loss around loaded titanium (Ti-SLA) and zirconia (ZrO2-ZLA) implants using a canine model. Materials and Methods: Forty sandblasted and acid-etched titanium and zirconia implants were alternately placed in the mandibles of five canines (20 Ti-SLA, 20 ZrO2-ZLA). Implants were restored after 6 weeks of unloaded healing. After 4 weeks of functional loading, oral hygiene procedures were stopped and experimental peri-implant bone loss was initiated by placing cotton ligatures. After 8 weeks of active progression, ligatures were removed and plaque was allowed to accumulate for another 16 weeks of spontaneous progression (without ligatures). Standardized radiographs were taken at implant placement, at functional loading, and every 2 weeks during active and spontaneous progression of bone loss. Results: Before ligature placement, all implants were successfully osseointegrated and no clinical or radiographic signs of peri-implant infections were detectable. Two weeks after ligature removal, one titanium implant was lost; however, no zirconia implant failures were observed during the study. Radiographically, zirconia implants revealed statistically significantly less crestal peri-implant bone loss compared to titanium implants at the end of the active progression period (Ti-SLA: 3.92 mm; ZrO2-ZLA: 2.65 mm; P < .01); however, no significant differences occurred after the spontaneous progression period (P = .6). Combining the active and spontaneous progression periods together, zirconia implants demonstrated significantly reduced peri-implant bone loss compared to titanium implants (Ti-SLA: 3.76 mm; ZrO2-ZLA: 2.42 mm; P < .01). Conclusion: These results demonstrate a significantly reduced ligature-induced inflammation and bone loss for ZrO2-ZLA implants compared to Ti-SLA implants in the canine model.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2019 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help