Comparative Study of Immediate Loading on Short Dental Implants and Conventional Dental Implants in the Posterior Mandible: A Randomized Clinical Trial

Kritsada Weerapong, DDS/Siripong Sirimongkolwattana, DDS, MSc/Thanapat Sastraruji, PhD/Pathawee Khongkhunthian, DDS, Dr Med Dent


PMID: 30521662
DOI: 10.11607/jomi.6732

Purpose: Immediate dental implant loading has been investigated with favorable results. However, short implants have not been investigated in this treatment option. This study compared the clinical outcomes and survival rates of immediately loaded short and conventional-length dental implants in replacing mandibular molar teeth. Materials and Methods: Forty-six implants (23 short dental implants and 23 conventional dental implants) in 46 patients were included in the study. Provisional computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic crowns were cemented to the abutments and immediately loaded. Several clinical parameters were recorded and statistically analyzed at 4-month and 1-year follow-up. Results: Two short implants lost integration, and one conventional implant failed. No statistically significant difference between the two implant types was found (P = 1.00). Minor complications were recorded; three provisional crown fractures were found in the short implant group and two provisional crown fractures in the conventional implant group. There was no significant difference in implant stability quotient values for short or conventional implants between baseline (short: 73.86 2.38, conventional: 75.05 3.26, P = .088), 4 months after loading (short: 72.37 1.35, conventional: 72.89 1.87, P = .165), and 1 year after loading (short: 74.60 2.03, conventional: 75.35 2.66, P = .296). The mean marginal bone level loss 4 months postloading was 0.28 0.29 mm for short implants and 0.25 0.25 mm for conventional implants (P = .73), and at 1 year postloading was 0.33 0.47 mm for short implants and 0.26 0.27 mm for conventional implants (P = .554); there was no statistical difference between the two implant types. Conclusion: The immediate loading of short implants is comparable to conventional-length implants in terms of implant survival, marginal bone level change, and implant stability quotient value.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2019 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help