Home Subscription Services
 
   

 
Journal of Laser Applications
Jola Home Page
About the Editor
Editorial Board
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JOLA

 

The Journal of Oral Laser Applications

Edited by Prof Dr Andreas Moritz and Prof G. Lynn Powell

Official publication of the European Society for Oral Laser Applications

ISSN (print) 1473-7809 • ISSN (online) 1867-5611

Publication:
JOLA
Winter 2008
Volume 8 , Issue 4

Pages: 245-255
Back
Share Abstract:

Morphological Study on Apicoectomy by High-Powered Er:YAG Laser

Shimizu, Takashi / Koba, Kenji / Kinoshita, Jun-Ichiro / Matsumoto, Koukichi

Purpose: In order to investigate the possibility of using the Er:YAG laser for apicoectomy and root-end sealing, the procedure time, dye penetration at the site of root-end sealing, and surrounding morphological differences were investigated. Materials and Methods: In 48 extracted human mandibular second premolars, root canal therapy was performed in the conventional manner. The Er:YAG laser was used for apicoectomy at either 3, 5, or 7 W. After preparing a root-end cavity about 5 mm deep, root-end sealing was performed using amalgam or light-cured resin. For control, an engine-driven fissure bur was used. Next, the root apex was polished, and dye penetration was assessed at depths of 1, 2, 3, and 4 mm. Morphological observations were carried out by x-ray imaging, stereoscopic microscopy, and scanning electron microscope (SEM). Results: When compared to the conventional rotary cutting device, the time required for 5- or 7-W laser apicoectomy was significantly shorter. The cut dentin surface in the laser application group was smooth, and carbonization, fissures, and marked evaporation were not seen. Dye leakage was only slight, with no significant difference between the laser and control groups (p < 0.01). Conclusions: The time for apicoectomy using the Er:YAG laser was shorter when compared to apicoectomy using the engine-driven rotary cutting device, and the level of dye leakage was comparable to the conventional method. The cut surface for root-end sealing had no residual smear layer and was clean. Favorable results were obtained with 3-W laser application in terms of cut surface condition, therapy time, and sealant gap.

Keywords: Er:YAG laser, apicoectomy, root-end sealing, leakage test, treatment time, SEM

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog