Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

January/February 2011
Volume 13 , Issue 1



Pages: 71 - 78
Back
Share Abstract:

Nanoleakage of Luting Agents for Bonding Fiber Posts After Thermomechanical Fatigue

Bitter, Kerstin / Perdig„o, Jorge / Hartwig, Christian / Neumann, Konrad / Kielbassa, Andrej M.

Purpose: To investigate the depth of nanoleakage of four luting agents for bonding fiber posts after thermomechanical fatigue. Materials and Methods: Twenty-four extracted human anterior teeth were endodontically treated, sectioned at the cementoenamel junction, and restored with fiber posts using four commercially available resin cements with the corresponding core buildup materials (n = 6): Panavia F 2.0/Clearfil DC Core Automix (Kuraray), Variolink II/Multicore Flow (Ivoclar Vivadent), RelyX Unicem/Filtek Z250 (3M ESPE), and Multilink Sprint/Multicore Flow (Ivoclar Vivadent). The specimens received all-ceramic crowns and were subjected to thermomechanical fatigue (1.2 million cycles). After cutting off the crowns, the roots were isolated with nail polish except for a 1-mm rim around the root canal, and immersed in 50 wt% ammoniacal silver nitrate solution for 24 h. The specimens were sectioned perpendicular to the long axis of the tooth into four slices, fixed, dehydrated, and processed for FE-SEM. Leakage was analyzed using backscattered FE-SEM and EDS. Results: The depth of nanoleakage was significantly affected by the factor resin cement (p < 0.015; Kruskall-Wallis). Multilink Sprint resulted in significantly deeper penetration of silver particles than the other materials (p < 0.05; Mann Whitney U-Test). Conclusion: Hybridization of the root canal dentin created by self-etching or etch-and-rinse adhesive systems demonstrated distinctive nanoleakage up to 0.8 mm, whereas the self-adhesive resin cement RelyX Unicem was able to prevent distinctive leakage at this penetration depth. However, none of the investigated luting systems would be able to hermetically seal the root canal if leakage occurred around the margins of the coronal restoration.

Keywords: root canal dentin, resin cement, FE-SEM, nanoleakage, fiber post

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog