Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

January/February 2011
Volume 13 , Issue 1

Pages: 23 - 29
Back
Share Abstract:

Enamel Margin Integrity of Class I One-bottle All-in-one Adhesives-based Restorations

Blunck, Uwe / Zaslansky, Paul

Purpose: To evaluate marginal adaptation of Class I restorations in enamel using contemporary one-bottle all-in-one adhesives, stressed by thermocycling (TC) and mechanical loading (ML). Materials and Methods: Ninety-six extracted human molars were prepared (standard Class I cavities: 3 mm deep, 6 mm wide mesio-distally, and 4 mm wide bucco-lingually). Twelve adhesive systems were used: OptiBond FL (OPT), Clearfil SE Bond (CSE) and Adper Prompt L-Pop (PLP) as controls, compared with nine one-bottle all-in-one adhesives – AdheSe One (AHO), Adper Easy Bond (EB), Bond Force (BF), G-Bond (GB), iBond Self Etch (IB), One Coat 7.0 (OC), OptiBond All-in-one (OPA), Clearfil Tri-S-Bond (TSB), Xeno V (XV). All teeth were restored using Filtek Z250 placed in three (one horizontal, two oblique) increments. Enamel margins were evaluated following 21 days of water storage, after thermocycling (2000 cycles: 5°C to 55°C), and after mechanical loading (150,000 cycles, 50 N). After each step, replicas were produced and quantitative SEM margin analysis was performed (200X) using defined criteria. Results: The median values of % continuous margin following TC and ML, respectively, were: OPT(98.6/96.2), CSE(95.4/90.9), BF(81.7/68.1), GB(81.1/65.0), OPA(83.0/68.1), OC(64.1/41.3), TSB(59.3/42.2), EB(57.1/42.6), IB(38.4/27.6), PLP(36.6/21.5), XV(45.0/30.0), AHO(17.7/5.4). Statistical evaluation (Kruskal-Wallis test with Bonferroni adjustment, p < 0.05) revealed the following ranking for ML: OPT=CSE>BF=OPA=GB>OC=EB=TSB=XV =IB=PLP>AHO. Conclusion: All one-bottle all-in-one adhesives exhibited statistically significant lower marginal qualities in enamel compared to the etch-and-rinse system OPF and the two-step self-etching system CSE. The results obtained for GB, OPA and BF, however, were better than for the other all-in-one adhesives.

Keywords: marginal quality evaluation, Class I, adhesive system effectiveness, thermocycling, mechanical loading

Full Text PDF File | Order Article

 

 
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog