Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

Winter 2000
Volume 2 , Issue 4



Pages: 259-269
Back
Share Abstract:

Field-Emission Scanning Electron Microscopy of Resin-Dentin Interface Morphology of Seven Dentin Adhesive Systems.

Tanumiharja, Maria; Burrow, Michael F.; Tyas, Martin J.; Carpenter, Jocelyn

Purpose: The purpose of this study was to evaluate the resin-dentin interface morphology of 7 resin-based dentin adhesive systems (Solid Bond, EBS-Multi, PermaQuik, One Coat Bond, Gluma One Bond, Prime & Bond NT/NRC, and Clearfil Liner Bond 2V). Materials and Methods: Fourteen dentin disks 1.0 mm thick were obtained from superficial occlusal dentin of extracted human third molars, and finished with wet 600-grit silicon carbide paper. Two dentin disks were bonded using each of the adhesives above according to the manufacturers’ instructions, and a thin layer or flowable resin composite was applied. The specimens were kept in tap water for 24 h at 37C, and then assigned to one of two observational techniques: a fracture technique and an acid-base technique. Fracture technique: shallow grooves were cut, fixed in 10% buffered formalin, and dehydrated in an ascending ethanol series up to 100%, critical-point dried, and fractured along the prepared grooves. Acid-base technique: the specimens were embedded in epoxy resin, sectioned through the center, polished with diamond paste down to 0.25-m particle size, and treated with 10% orthophosphoric acid for 10 s and 5% sodium hypochlorite for 5 min. All the specimens were mounted on aluminum stubs, gold sputter coated, and observed using field-emission scanning electron microscopy (FE-SEM). Results: All the dentin adhesive systems showed hybrid layer formation, but the thickness varied depending on the bonding system used. The self-etching priming systems (Prime & Bond NT/NRC and Clearfil Liner Bond 2V) showed the thinnest hybrid layer at 1 to 2 m, whereas the single-bottle system (Gluma One Bond) exhibited the thickest hybrid layer at 8 to 16 m. Conclusion: The ultramorphological structures of dentin bonding systems are determined by the composition of each system. Characterization of the interface of the adhesive system using the fracture technique provides additional information regarding the pattern of resin infiltration in some dentin bonding systems.

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog