Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

Winter 2001
Volume 3 , Issue 4



Pages: 295-308
Back
Share Abstract:

Reliability of In Vitro Microleakage Tests: A literature Review.

Raskin, Anne; D’Hoore, William; Gonthier, Samuel; Degrange, Michel; Déjou, Jacques

Purpose: The literature contains conflicting data about in vitro microleakage evaluations and their usefulness and reliability. No standardization has yet been established. Here we consider features of published studies that might affect the results of the in vitro microleakage tests. Materials and Methods: We reviewed 144 in vitro microleakage studies, published in 14 international reviews between 1993 and 1998, which comprised 917 sets or groups of experiments. The published studies were entered in a database and compared using selected literature criteria: sample, cavities, restoration procedures, thermocycling and mechanical cycling, evaluation method. Results: The methods employed vary widely. The most frequent methodological choices (%) were (1) specimen storage after extraction: duration (unspecified, 59.2), medium (distilled or deionized water, 33.8), temperature (unspecified, 52.2), additives (none. 47.0); (2) aging method (79.1): duration before aging (< 24 h, 35.9); medium and temperature of storage before aging (distilled or deionized water, 26.8, 37°C, 54.3); (3) medium of cycling (tap water, 50.5), number of cycles ([250-500], 34.6), number of baths (2, 84.0), bath temperature (5°C to 55°C, 60.6), immersion dwell time (30 s, 44.3); (4) tracer: type (basic fuchsin, 40.7), time of immersion (after thermocycling and/or mechanical cycles, 64.1), immersion duration (basic fuchsin: 24 h, 59.5); assessment of dye penetration of sections (91.7); direction (perpendicular, 88.5), number (1, 47.1). Conclusion: The great variability in the methods used in these 144 studies prevented meta-analysis and comparison of the results, thus reducing the value of these methods. [ABSTRACT FROM AUTHOR]

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog