Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

Summer 2001
Volume 3 , Issue 2



Pages: 145-152
Back
Share Abstract:

Bonding Strength to Two Different Surfaces of Dentin Under Simulated Pulpal Pressure

Belli, Sema; Ünlü, Nimet; Özer, Füsun

Purpose: The purpose of this in vitro study was to measure and compare the in vitro shear bond strengths (SBS) of the following dentin bonding systems to different dentin surfaces under simulated pulpal pressure: Liner Bond 2 (self-etching) (LB2), Liner Bond 2V (self-etching) (LB2V), Opti Bond Solo (single component) (OBS). Fuji Bond LC (filled) (FBLC), Prime & Bond 2-1 (single component) (P&B2-1), and Solid Bond (total etching) (SB). Materials and Methods: Occiusal and buccal surfaces of 60 extracted human molars were prepared to expose the dentin bonding surface. After being wet ground with 600-grit abrasive papers, teeth were randomly assigned to 6 equal groups of 10 each. The dentin surfaces were treated with the bonding systems mentioned above, and resin composite cylinders (Clearfil AP-X) were built up under simulated pulpal pressure when diluted bovine serum was used as the pulpal fluid. After one day of storage in 37°C water, the specimens were shear tested to failure on an Instron machine. Results: The data were statistically analyzed with the Student’s t-test and a post hoc Tukey test. Comparing buccal surfaces, the post hoc Tukey test indicated no significant differences among all the test groups (p> 0.05). On occlusal surfaces, the post hoc Tukey test indicated significant differences among the tested groups (p < 0.05). The Student’s t test revealed significant differences between the occlusal and buccal shear bond strength values in LB 2, LB2V, and SB groups (p < 0.05). Conclusion: The strength of adhesion to dentin depends upon both the adhesive system used - with self-etching systems tending to show higher bond strengths than the other materials tested - and the location of the dentin, with significantly higher SBS being found on buccal surfaces in 3 of the 7 tested bonding systems.

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog