Home Subscription Services
 
   

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

Spring 2002
Volume 4 , Issue 1



Pages: 73-80
Back
Share Abstract:

Mechanical Properties and Bond Strength of Glass-ionomer Cements

Pereira, L˙cia Coelho Garcia/Nunes, Margareth Calvo Pessutti/Dibb, Regina Guenka Palma/Powers, John M./Roulet, Jean-Franšois/Navarro, Maria Fidela de Lima

The objective of this study was to evaluate the mechanical properties and bond strength of glass-ionomer cements (GICs) and resin-modified GICs (RM-GICs) that are indicated as restorative materials for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens for the diametral tensile strength (DTS) test and fifteen cylindrical specimens for the compressive strength (CS) test were made of each GIC: Ketac-Fil, Ketac-Molar (ESPE), Fuji IX and Fuji PLUS (GC). Forty human molars were sectioned and embedded in resin with either buccal or lingual surfaces exposed for the tensile bond strength (TBS) test. The surface was ground until a flattened area of enamel or dentin was obtained. After conditioning, inverted truncated cones of GICs were prepared on the flat tooth surfaces. The powder:liquid ratio of Fuji PLUS was adjusted for restorative purposes. Prior to testing, specimens were stored for 24 h (TBS test) and for 1 h, 24 h, and 7 days (CS and DTS tests) in deionized water at 37░C. They were then loaded at a crosshead speed of 1.0 mm/min for CS and 0.5 mm/min for DTS and TBS tests until failure occurred. The data were submitted to two-way ANOVA at 0.05 level of significance, followed by a Tukey-Kramer test for multiple comparisons. The mean CS values ranged from 90.27 to 170.73 MPa and DTS means from 6.21 to 22.32, with test periods from 1 h to 7 days. The means for TBS ranged from 4.90 to 11.36 MPa and from 2.52 to 5.55 MPa in enamel and dentin, respectively. No differences were found between materials with the CS test except at 1 hour. The resin-modified GIC (RM-GIC) had the highest DTS, with no changes between the test periods, and the highest TBS for both enamel and dentin. Among the GICs tested, RM-GIC showed higher values of DTS and TBS.

Full Text PDF File | Order Article

 

 
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog