Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
The Journal of Adhesive Dentistry
JAD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: JAD

 

The Journal of Adhesive Dentistry

Edited by Jean-François Roulet

ISSN (print) 1461-5185 • ISSN (online) 1757-9988

Publication:

Summer 2003
Volume 5 , Issue 2

Pages: 121-127
Back
Share Abstract:

Microtensile Dentin Bond Strength of Self-etching and Single-bottle Adhesive Systems in Different Cavity Configurations

Mallmann, A. / Soares, F. Z. M. / Placido, E. / Ferrari, M. / Cardoso, P. E. C.

To evaluate the bond strength of a self-etching (Clearfil SE Bond) and a single-bottle (Excite) adhesive system using two cavity configurations (C-factors 5 and 1). Class I cavities (3 x 4 x 2.5 mm) were prepared in 28 extracted human molars using diamond burs under water cooling. Teeth were divided into 4 groups: G1: Excite, C-factor 5; G2: Excite, C-factor 1; G3: Clearfil, C-factor 5; G4: Clearfil, C-factor 1. To determine C-factor 5, systems were applied to all cavity walls according to the manufacturers’ instructions (5 bonded, 1 unbonded). For C-factor 1, lateral walls were isolated using nail varnish, and adhesive systems were only applied to the pulpal floor (5 unbonded, 1 bonded). Cavities were restored using Tetric Ceram composite resin (Ivoclar/Vivadent), and bulk light cured for 40 s (500 mW/cm2). Teeth were stored in distilled water for 24 h at 37°C, and then sectioned using a diamond disk, yielding stick-shaped specimens with a bonded area of approximately 0.8 mm2. Specimens were submitted to the microtensile bond test at a rate of 1 mm/min speed in a universal testing machine. Resin-dentin bond strengths (MPa) were submitted to ANOVA and Tukey’s tests (p < 0.05) [number of specimens]: G1 = 35.8b [43]; G2 = 48.9a [55]; G3 = 45.9a [60]; G4 = 49.0a [53]. There was no statistically significant difference between adhesive systems for C-factor 1. For C-factor 5, Clearfil SE Bond produced higher values when compared to the other group. Changes in C-factor only affected the total-etch adhesive system tested. This may be a result of the different filler volume in the self-etching system, and not of the bonding technique itself.

Full Text PDF File | Order Article

 

 
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog